Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFORESTER APARTMENTS
Address2025 TIMBER OAKS LN
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/25/2026
Final Score @ Grade
32
General Comments30 Day Intent to Suspend (ITS) for pool wall tiling, coping/deck in good repair/secure/no offsets, weirs, gates and spare pump baskets. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. “W” status Inspection with Jose Ortega Pool not heated. No night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool wall tiling missing, damaged in multiple places. .2537b(8) Damaged face plates or fittings shall be repaired or replaced. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 2 of 4 weirs missing. .2518(k) Replace missing weirs. *permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope to buoy tangled and inaccessible for emergency. Operator untangled and corrected. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. .2530(a) Lifesaving equipment should be conspicuously and conveniently located.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate at front and side not latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. *Permit item Fencing by back side gate has original construction, horizontals less than 45” in height. Pool built 1999. .2528(a) Horizontals shall not be located less than 45" in height.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Coping cracked greater than 1/2”, not secured and loose. .2537(2) Decks shall be kept in good repair. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2537(3) There shall be no loose coping. *permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No No spare pump baskets for either pump. Pumps: Sta Rite P6RA6G-207L and Pentair CHII-NI-2FE .2518(e) Provide a spare basket for pump. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals in pump room. No 3’ clearance. Original construction. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labeling on piping faded, not identified. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Observed shower non operational. 2526(h) Shower(s) shall be provided.