| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
0
|
Procedures for responding to vomiting & diarrheal events |
No |
No
|
No |
2-501.11 A food establishment shall have written procedures for employees to follow when responding to vomiting or diarrheal events. -Pf Facility does not have policies at time of inspections. CDI PIC has obtained information from web site and posting |
|
8
|
2
|
Hands clean & properly washed |
No |
No
|
Yes |
2-301.11 Keep hands and arms clean. -P No handwashing station was found functioning. |
|
10
|
1
|
Handwashing sinks supplied & accessible |
No |
No
|
No |
5-205.11 (A) A handwashing sink shall be maintained so that it is accessible at all times for employee use Pf. Hand Washing sink was not available.
5-203.11(A)/5-204.11 Establishment is required to maintain the required number of hand-washing sinks required by Law and for convenient use by employees in areas required by the NC Food Code. - Pf |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
No |
No
|
No |
4-501.114 Maintain sanitizer at correct concentrations when being used to sanitize. -P Sanitizing was not observed. CDI PIC was instructed in proper sanitizing procedures. |
|
20
|
1.50
|
Proper cooling time & temperatures |
No |
No
|
No |
3-501.14(B) Quickly cool TCS foods that are prepared from room temperature ingredients. Food must be to 41F within 4 hours. -P. Bean, Rice, Hotdogs were found over 45F held over 24 hrs. CDI Food was voluntarily discarded. |
|
23
|
0
|
Proper date marking & disposition |
No |
No
|
No |
3-501.17 Date mark/label all TCS foods that are ready-to-eat once opened or prepared and held more than 24hrs. -Pf No dare marking was observed. CDI PIC was instructed in date marking procesures. |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
No |
No
|
No |
4-301.11 Provide equipment in number and capacity so that cooling, heating, and holding temperatures are achieved. -Pf Lower cooler was packed with food over 24 hours. CDI PIC was instructed in keeping food spaced out and taking temperatures throughout the day. |
|
37
|
0
|
Food properly labeled: original container |
No |
No
|
No |
3-302.12 Label all working containers of food (oils, spices, salts, flour, sugar) except food that is easy to identify such as dry pasta. No labeling was observed . |
|
38
|
0
|
Insects & rodents not present; no unauthorized animals |
No |
No
|
No |
6-202.15 Protect outer openings of establishment from insect or rodent entry. flies were observed. |
|
41
|
0
|
Wiping cloths: properly used & stored |
No |
No
|
No |
3-304.14(D) Maintain dry wiping cloths free of visible debris and soil. Maintain sanitizer containers for in-use cloths free of visible debris and soil. Wiping clothes were observed on counters. |
|
43
|
0
|
In-use utensils: properly stored |
No |
No
|
No |
3-304.12 (A) In-use utensils in TCS food, must be stored with handles above the food and top of the food container. Handles were observed in products. |
|
44
|
0
|
Utensils, equipment & linens: properly stored, dried & handled |
No |
No
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Equipment was observed wet on shelves. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-502.11(A) Maintain utensils in good repair. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
No |
4-301.12(B) Sink compartments shall be large enough to accommodate immersion of the largest equipment and utensils.-Pf Two compartment sink noted with debris and not functioning. CDI PIC was instructed in the use of the two compartment. |
|
49
|
0
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Grease build up on vents and sides of ovens. |
|
50
|
0.50
|
Hot & cold water available; adequate pressure |
No |
No
|
No |
5-103.11(B) Provide sufficient hot water to meet the peak hot water demands.-Pf Running water was not observed. |
|
51
|
1
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-202.13 An air gap between the water supply and flood level rim shall be at least twice the diameter of the water supply inlet and not less than 1 inch.-P. Nozzle to sink was observed below sink rim edge. CDI Nozzle will be replaced |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Holes and cracks in floor tiles were observed. |