47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 - Good Repair and Proper Adjustment: Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted. Observed split gasket in WIF. Observed bottom door of WIC broken. REPLACE OR REPAIR. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.12 - Cleaning, Frequency and Restrictions: All physical facilities shall be maintained in good repair and shall be cleaned as often as necessary to keep them clean and by methods that prevent contamination of food products. Observed floors, walls and ceilings with microbial growth. Increase cleaning frequencies. REPEAT. |
|
56
|
0.50
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-501.14 - Cleaning Ventilation Systems, Nuisance and Discharge Prohibition: Change the filters and clean the intake and exhaust air ducts so they are not a source of contamination by dust, dirt or other materials. Observed vents in the meat prep area and in WIC with build up. CLEAN. |