Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Wake County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSMITH FARM AMENITY POOL
Address2950 FARMHOUSE DR
 
City/State/ZIP
APEX NC 27502
Premise Type50 - Seasonal Swimming Pool
CountyWake
Inspection Date 4/23/2026
Final Score @ Grade
10
General CommentsPool permit valid from 4/23/26 to 10/31/26. No night swimming! 104,141gal; 289gpm min turnover flowrate. To meet fixture count for restroom facilities, restrooms in clubhouse in addition to pool house restroom, must be accessible to pool patrons and are subject to inspection and compliance. Grill area may not be used when pool permit expires unless divider fence/gate is corrected to remove any footholds less than 45 inches. Fence partition that was placed for clubhouse to use deck area during off season is being removed once permit is issued. All windows have 4" spacers. Doors that enter into pool deck are self-closing and latching. NOTE: VGB field verification was completed today. 310 GPM/ 2 (2 FILTRATION PUMPS, EACH FILTRATION PUMP ON ONE UNBLOCKABLE MAIN DRAIN) = 155 GPM PER DRAIN COVER WHICH IS LOWER THAN MAX GPM FOR DRAIN COVERS.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Parts of the fence on left side of pool near clubhouse fence had gaps appx 4". Repair. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. The bather entrance gate closest to the club house was slow to close. The CPO repaired it to close and latch easily after being used. NOTE: Left entrance gate is self-closing, self latching to meet our rules; however the push bar is hard to press open from the inside of the pool causing potential egress issue (fire code). CPO has called to have it repaired. CPO is having this gate locked and bathers will use the working right entrance gate until repaired.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Emergency pool sign included "RD" instead of "DR" as confirmed by 911. CPO changed sign to reflect DR in the address.