NameBEAVER CREEK TOWNHOMES POOL
Address201 FANTAIL LANE
 
City/State/ZIP
APEX NC 27523
Premise Type50 - Seasonal Swimming Pool
CountyWake
Inspection Date 9/1/2026
Final Score @ Grade
16
General CommentsCompliant investigation for cloudy water is unsubstantiated. Water is crystal clear and main drains are clearly visible today. Total Alkalinity (TA) is 120ppm (maintain range 80-120PPM) Cyanuric Acid (CA) is greater than 100PPM (maintain less than 100 PPM , ideal range 30-50PPM) Record TA and CA in CPO log book weekly. CPO states the pool will be closing next week for the season and water will be drained to power wash the walls. This should correct the high CA levels. Phone checks out ok. Two ring buoys each have ropes that were tangled together. Remind patrons not to play with life saving devices. CPO corrected during inspection, untangled ropes and properly hung buoys on hooks on opposite sides of pool. 3 skimmer weirs are missing and need replacing. Observed missing concrete patch on decking, greater than 1/2 inch deep, near pool edge. please repair it. Noted: EQ are disabled internally in skimmers, currently still have Paramount covers in place on pool walls. Water on pump room floor indicates a leak somewhere. small leak observed on sand filter watch glass. Find all leaks and repair as needed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) 3 of 5 weirs are missing. Replace missing weirs.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment should be conveniently located. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Two ring buoys provided had tangled ropes. CPO untangled ropes and corrected the issue during inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter reading is low compared to minimum turnover rate. It might not be working properly. Repeated issue.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Pump room floor is wet around pump and sand filters. Find and Repair any leaks.