Inspection Date 10/29/2026
Final Score @ Grade
20
General CommentsObserved pool rules signage state pool open from 9AM - 8PM. However, pool is not approved for night swimming, therefore, signage shall state that pool open from Dawn - Dusk/Sunrise - Sunset. PIC corrected signage to state pool open from 9AM - Dusk. Filtration Pump must remain at 3450 RPM - or - flow meter must remain at 146 - 196 GPM to meet turnover and flow restriction of filters. Inspection completed by EHS Alexander DeCristo and Chad Gambill.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. *Observed - Chlorine below 1ppm. *CDI - PIC corrected chlorine to 6ppm.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Observed - Daily drain checks missing from pool and spa records. *CDI - PIC added Main Drain checks to record log book.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. *Observed - No pool phone number provided on emergency phone signage. Establishment recently switched to Kings III leading to change of signage. *CDI - PIC provided pool phone number to emergency phone signage
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) The flow meter installed shall be capable of measuring the minimum turnover rate and permit restriction, if applicable. *Observed - Flow Meter displaying below the required GPM stated in Field Book Notes. *CDI - PIC cleaned flow meter and turned up the Spa pumps RPMs to 3450.