24
General CommentsIssued immediate suspension for chlorine and pH levels. Pool is to remain closed until items are back in compliance. Please call James Bjorneboe at 704-507-6820 to schedule revisit. General Comment. Consider changing phone that can transmit both physical address and telephone number to 911.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed no chlorine in spa. Maintain chlorine at a minimum of 1.0ppm. .2535(4) Maintain chlorine at least 1.0 ppm.
3 6 Water quality: pool water pH No No No Observed pH at 8.2. Maintain between 7.2 and 7.8. .2535(1) Maintain pH at 7.2 to 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no daily or weekly records kept on site. Keep and maintain records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed excessive debris in skimmers, Keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed two sets of doors leading to deck not self closing/ self latching. Correct. .2537(b) All gates and doors shall be self-closing, self-latching.