Premises Information

Return to Inspections
NameTRAILSIDE NODA
Address1028 STITCH BEND WY
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 7/16/2026
Final Score @ Grade
34
General CommentsInspection conducted with CPO Chris Munoz. Facility needed a 5% flow meter installed on filtration system. New Aquastar FM-30 flow meter installed. New PDSC form filled out and approved. Pool is now maintained by Swim Club Management. Copy of inspection also emailed to the management company. Blower motor for spa jets not working. If replaced ensure an electrical permit and passing inspection are obtained form Mecklenburg County Code Enforcement. Intent to suspend issued 5) 16) Contact Will Harrison (704) 507-6824 to schedule visit to verify emergency phone has been corrected and to verify sump information.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
4 6 Water quality: water temperature of heated pool No No No Spa water temperature > 104F. .2535(12) Heated spa temperature greater than 104 F. Maintain spa temperature at 104 F or below. - Heater turned down and corrected to 103.8F.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent records. Be sure to note if pool was closed. No Cyanuric Acid or pool maintenance activities noted for July. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. - Intent to suspend item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Spa jet sump information on PDSC form does not appear to match the PDSC form. .2539(b) All suction outlets, except vacuum ports, shall be protected by anti-entrapment cover/grates in compliance with APSP-7/APSP-16. - Will follow up with facility to correct.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing 1 of 3 weirs. .2518(k) Replace missing weirs.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gap > 1/2” between gate and post at the top of two of the gates. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Kings III phone has correct address. Number transferred to local 911 is the address for the office, not the address for the pool. .2530(f) Emergency notification systems (monitoring services) must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer the phone number and address for the phone to 911. - Will follow up with facility to correct. Failure to correct in 2 weeks will result in a permit suspension.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. Spa heater not labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower not functioning. .2526(h) Shower(s) shall be provided.