Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTRAILSIDE NODA
Address1028 STITCH BEND WY
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/16/2026
Final Score @ Grade
24
General CommentsInspection conducted with CPO Chris Munoz. Pool is now maintained by Swim Club Management. Copy of inspection also emailed to the management company. Pool heated. Heater off at time of inspection. Bonding wire not attached to filtration or jet pump motors. G.S. 130A-(2)3 Bonding wire shall be attached to the pump motor. - Corrected. Intent to suspend issued 5) 16) 24) Contact Will Harrison (704) 507-6824 to schedule visit to verify emergency phone has been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent records. Be sure to note if pool was closed. No Cyanuric Acid or pool maintenance activities noted for July. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions. One handrail at sunshelf missing escutcheon plate. .2521 Install handrails per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gap > 1/2” between gate and post at the top of two of the gates. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Kings III phone has correct address. Number transferred to local 911 is the address for the office, not the address for the pool. .2530(f) Emergency notification systems (monitoring services) must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer the phone number and address for the phone to 911. - Will follow up with facility to correct. Failure to correct in 2 weeks will result in a permit suspension.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter reading less than minimum turnover of 90 GPM. .2519(b) The water circulation system shall circulate and filter the entire volume of public swimming pool water at least 4 times in 24 hours. - Intent to suspend item.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. Pool heater not labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower not functioning. .2526(h) Shower(s) shall be provided.