10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.14 Post a handwash sign at each handsink. Observed no hand washing signage at hand washing sink near register.
5-205.11 (B) A handwashing sink may not be used for purposes other than handwashing Pf. Observed employee rinsing blue knife in hand washing sink near register. CDI - PIC educated employee on using 3-comp-sink for W/R/S instead of hand washing sink. |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf. Observed food debris on tomato slicer, and stainless steel bowls with secondary squeeze stored clean on storage rack. CDI - PIC moved items back to 3-comp-sink to be w/r/s.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg , How to Test Sanitizer https://youtu.be/y0SjmnabFaY , and Cleaning and Sanitizing Food Contact Surfaces https://youtu.be/av1Rbh-lh08 . |
|
22
|
3
|
Proper cold holding temperatures |
Yes |
Yes
|
No |
REPEAT
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed steak above 41F in WIC that was prepared around 9:30AM. CDI - PIC voluntarily discarded pan of steak.
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
49
|
0.50
|
Non-food contact surfaces clean |
Yes |
Yes
|
No |
REPEAT
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed several stainless steel food containers with sticker residue stored clean. CDI - PIC moved items back to 3-comp-sink. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
REPEAT
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed ceiling tile with dust and debris build up above 3-comp-sink and storage of clean equipment.
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed a few ceiling tiles missing above WIC and WIF. |