Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHANOVER DILWORTH
Address711 E MOREHEAD ST
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/16/2026
Final Score @ Grade
18
General Comments30 Day Intent to Suspend (ITS) issued for records, gates and feeder shutting off with pump. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. “W” status. No night swimming. Pool heater stays off. Flow indicating 70 gpm after backwash. 1)Filtration pump flow meter shall remain operable. Flow shall be kept at 82 gpm to 120 gpm to meet turnover and flow restriction of number of returns. features. No permit action for this item at this time. Monitor and advised correction before it worsens. If water quality becomes an issue a new pump may be required. 2) No seating on column side of pool due to decorative Inspection with Elliott Odie

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No main drain checks on records and forms ran out. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *permit action
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Furniture in front of life saving equipment. .2530(a) Lifesaving equipment should be conspicuously and conveniently located. Keep accessible in case of emergency. Operator moved furniture blocking equipment and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gates not self-latching/self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. *permit item
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automatic feeder not indicating flow or no flow when pump is off. Adjusted to manually feed and feeders did not stop (mechanism that feeds continued to operate and plug did not drop to stop flow). .2535(6) Automatic chlorine and bromine, and acid feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. *permit item