NameHANOVER DILWORTH
Address711 E MOREHEAD ST
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/3/2024
Final Score @ Grade
14
General CommentsOSV to pool with Tony Jajuga and Mike Hovis for return construction and operating permit inspection. All permits tied to the pool finaled except for M4271527, tied to Charlotte Mechanical and amenity space approval. Spoke with Code inspector, John Todaro. Ok to final. Contractor called in permit to final while onsite. Depth markers installed at 4 ft. 6 in. actual depth at 4 in. Pool is egg shaped. Plan shows 4 ft. 6 in. on center. Not addressed in plan review process. Contractor will correct to reflect value at 4 ft. - 4 ft. 6 in. on pool and wall or 4 ft. 3 in. Emergency phone calls back and answers; however, hangs up after a few seconds. Contractor will change phone to a phone that stays on when answered. Address/phone number posted with dialing instructions. Will verify both items in 2 weeks. If not corrected, permit action will be taken. Construction final passed. Holds released in system. Permit issued for no night swimming. An unannounced follow-up inspection will occur within 60 days after inspection. Permit Restrictions: 1) Filtration pump flow meter shall remain operable. Flow shall be kept at 82 gpm to 120 gpm to meet turnover and flow restriction of number of returns. 2) No seating on column side of pool due to decorative features. 3) Pool is not approved for salt as primary chlorination. 4) Heater is not approved until plans submitted to Code Enforcement and approved. Pool Width - 22 ft.; Rope Length - 33 ft. ; Max Depth 4 ½ ft. Filtration - Hayward HCP2000 Series HCP20153 pump with (2) Paramount SDX2 drain covers. EQ line covers are plugged in skimmer/plastered on wall. Feature - Hayward TristarXL HCP3020VSP, 2.7 THP with (3) Paramount SDX2 drain covers.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No log book provided since turnover of pool was 7/3. Ensure daily record keeping for chlorine, pH and main drain checks. Ensure weekly record keeping for total alkalinity and cyanuric acid.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Stenciled depth markers installed with paint chipped off. Repainted during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No >1/2" between post and gate on all three gates, lower sections. Horizontal on exterior of gates. Both corrected during the inspection - added piece to lower section to eliminate horizontal and also piece to barrier to make opening less than 1/2".