| Name | EVERLY | | Address | 421 W TREMONT AV
| | | | City/State/ZIP | | | Premise Type | 53 - Year-Round Swimming Pool | | County | Mecklenburg | | Inspection Date
| 4/13/2026 | | Final Score @ Grade | | | Conducted inspection with CPOs Larry and CJ. Pool remains in good standing and on A status.
Feature pump changed by manufacturer due to controller board issue. Submit updated PDSC to health department by end of the week.
EHS recommends lowering chlorine level for bather comfort.
Feature pump: 55gpm
Permit Restrictions: 1) Filtration flow meter shall remain operable. Flow shall be kept at 48 gpm to 138 gpm to meet turnover and flow restriction of suction lines. 2) Feature pump required at 1400 rpm or flow meter shall remain operable with flow at 62 gpm or less due to drain cover flow restriction. Suction Hazard.
Const. Date: 5/7/2024 Rope Length: 24' Night Swim?: N |
|