| Name | EVERLY | | Address | 421 W TREMONT AV
| | | | City/State/ZIP | | | Premise Type | 53 - Year-Round Swimming Pool | | County | Mecklenburg | | Inspection Date
| 7/2/2024 | | Final Score @ Grade | | | OSV to pool for return construction and operating permit inspection.
Jason Everett, CPO, and Mason Garrett, Hot Springs Pools, present during the inspection. Verified permit restriction of filtration at 80 gpm and install of flow meter on feature line with flow reading of 55 gpm during the inspection. Operating permit issued for no night swimming. An unannounced follow-up inspection will be completed within 30/60 days of permit issuance. The State permit is available on our website. Ensure log book for next inspection.
No Diving marker covered by handicap lift. Given one week to correct. Add additional no diving marker per code requirements, visible. Follow-up visit for chlorinator repair will occur on 7/3.
Some offset not greater than 1/2" at skimmer closest to main drains. Does not warrant repair at time of inspection; however, may require repair in the future if offset worsens.
Permit Restrictions:
1)Filtration flow meter shall remain operable. Flow shall be kept at 48 gpm to 138 gpm to meet turnover and flow restriction of suction lines.
2)Feature pump required at 1400 rpm or flow meter shall remain operable with flow at 62 gpm or less due to drain cover flow restriction.
Note: Barrier of pool is doors/windows located inside screened in porch.
Note: Verified backing tape on mirrors in restrooms.
Note: If signage changed by ownership, must meet wording and size requirements of the rule.
Pool Width 16 ft.; Rope Length 24 ft.; Max Depth 4 ½ ft.
Filtration Pentair Intelliflo3 VSF 011075 pump with (4) Hayward WG1031BHF2 2017 drain covers. EQ lines plugged in skimmer.
Feature Sta-Rite Supermax VS, 343001, 2.2 THP pump with (2) Pentair Starguard 500120 drain covers. |
|