NameRADBOURNE LAKE
Address3209 WESTBURY LAKE DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/30/2026
Final Score @ Grade
22
General CommentsPERMIT RESTRICTIONS: 1). Flow meter must remain operable. Flow shall not exceed 104 GPM due to filter and pipe size restrictions. Flow greater than 150 GPM exceed main drains. Suction Hazard. 2). Both skimmer lines must remain valves open at all times due to pipe size flow restrictions. - No Night Swimming permitted - CPO: Daniel Quintana Nava present during permit inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8.- Observed pH at 7. Fixed during inspection to 7.2
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs.- Observed a missing weir, items replaced at the time of inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Ladders shall have slip-resistant tread.- Observed two ladders on each side of the pool. One is missing all the slip resistant treads on all 3 steps. The other ladder is missing 2 treads. Replacement needed.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.- Observed rope length measured at 46ft. CPO untangled the rope, made it 50ft straight.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching.- Observed a gate leading to the outside and pump room not self latching. Fixed to work properly at the time of inspection.