| Name | COULWOOD SWIM CLUB | | Address | 409 COULWOOD DR
| | | | City/State/ZIP | | | Premise Type | 50 - Seasonal Swimming Pool | | County | Mecklenburg | | Inspection Date
| 6/28/2024 | | Final Score @ Grade | | | Scope of Work Pool raised to 5 ft. max depth. New equipment in pump room. Floor/floor drain existing and building existing (outside). New chemical storage room. Restroom shells are existing along with main building. New fixtures replaced in restrooms. Plumbing run for future slide. Slide not installed. Pump for slide not installed.
All items corrected from previous visit. Verified with pictures provided by Jeff Gaeckle. Construction final passed. Permit issued for no night swimming. Holds released in system.
Permit Restrictions:
1) VFD for filtration pump shall remain operable. Flow meter shall remain operable. Flow shall be kept at 463 gpm to 588 gpm to meet turnover and flow restriction of filters.
2) Aerator not approved for use while pool is open to public.
3) Left side door on double door entry into building must remain locked so that doors self-close, self-latch.
Note: Equipment room floor and floor drain existing. Restroom floor and floor drain existing.
Note: Maintenance gate at equipment room permitted with handle at 40” from ground due to building code.
Filtration - Pentair EQ1500, 15 hp pump with (12) VGBA-2017 Aquastar 18MFxxxxxx drain covers. EQ lines plugged in skimmer.
Aerator Hayward HCP20303 with (2) VGBA-2017 Aquastar 12MFxxx drain covers.
Slide No pump installed for slide at time of inspection. Future install approved with Hayward HCP20073. Slide and aerator pull through same suction line through 12x12 drain covers.
CMD Nova drain cover on hydrostat no suction.
Report emailed to Jeff Gaeckle. |
|