5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
No records since mid June. Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Disable skimmer equalizer lines by plugging the line under the skimmer basket and where the equalizer pipe exits the pool shell.
Two equalizer out of four caps missing in skimmer basket. Equalizers plugged on wall with plaster and plug. Replace missing inside caps. Intent to suspend item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Body hook not attached to pole. Operator reattached.
Ring buoy rope broken in half. Operator replaced and cut to approved 39’ length.
No permit action. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable.
Emergency phone not operational at beginning of visit. Operator corrected and emergency phone operational by end of inspection. No permit action. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Chemicals in pump room. Move to designated chemical storage room. |