NameWRENLEY THE
Address2022 WINTERS EVE DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/9/2024
Final Score @ Grade
16
General CommentsInspection conducted with CPO Ray Cruz. *Note* Pool is operated part of the week by Mass Pools, and part of the week by CPO certified onsite staff. Pool 2,544 sq ft. Needs 8 feet of deck clearance. Intent to suspend issued 8) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing 2 of 7 weirs. .2518(k) Replace missing weirs. One skimmer not plugged in the skimmer per state guidelines. .2518(k) Install skimmer per manufacturer specifications and plug per State requirements. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders loose. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Facility with two ring buoys, both with 60 foot throw ropes. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gaps > 4” through the fence in places. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Intent to suspend item. Gap > 2” under fence at far end of pool by steps. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item.