Premises Information

Return to Inspections
NameDRAKE, THE
Address9905 UNIVERSITY CITY BV
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/30/2026
Final Score @ Grade
8
General CommentsInspection completed with Don Benn present. Intent to suspend permit issued for underwater light not securely affixed to wall. Correct within 30 days or permit may be suspended. Contact Eli Freese at 704.621.2298 with questions. Note- 2 screws appeared rust colored on 1 of the main drains. The main drain itself is in good repair and an additional 2 screws in this drain did not appear rusted. Recommend replacing screws. Permit restrictions: 1. Pressure gauges must remain in place. Pressure readings shall be kept so that calculated head loss and corresponding pump curve flow is from 73GPM to 120 GPM to meet turnover and flow restriction of the number of returns (calculated TDH of pressure and vacuum combined shall be in range of 75’ to 95’ at 3450 RPM speed setting). Flow meter does not accurately read. 2. Sump pump must remain operable in backwash pit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one underwater light not securely affixed to wall niche. Repair so that light is flush with wall and in good repair. Intent to suspend the permit issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate not self closing. CDI- repaired.