Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWREN NORTHLAKE PHASE II
Address20011 PRESTWOOD CLUB CT
 
City/State/ZIP
CHARLOTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/24/2026
Final Score @ Grade
14
General CommentsInspection conducted with CPO Juan Merced. Issue with Kings III phone not being able to transfer call to 911. Came back from 2:05 - 2:35 PM to verify phone was corrected. Pump shall be set at 98 gpm to 141 gpm to meet turnover and flow restriction of the filter. Verified at 105 GPM today. Outer rope on ring bouy starting to fray. Recommend replacing with new US Coast guard approved ring buoy with 50 foot throw rope at least 1/4 inches in diameter. Intent to suspend issued 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of five weirs. .2518(k) Provide functional weirs. Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gaps > 2” under the fence in a few places. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item. Gaps > 1/2” between gate and post on two of the gates. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Kings III phone not able to transfer the call to local 911. .2530(f) Emergency phone shall remain operable. - Corrected. Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.