| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH over 8.2 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
*Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Calcium recorded as Cyanuric acid, Incorrect chemical readings, and maintenance checks not accurate.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit Item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed missing weirs at the time of the inspection.
.2518(k) Replace missing weirs.
*Permit Item |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
No diving and depth markers faded on the deck at the time of the inspection.
.2523(c) Depth markers and “No Diving” shall be 4 inches in height and of a contrasting color with the background, clearly visible.
*Permit Item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Missing slip resistant tread on the bottom ladder rung at the time of the inspection.
.2521(b) Ladders shall have slip-resistant tread. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Beckets were not properly secured so that they were no longer aligned per USCG issuance.
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
*Corrected - Operator adjusted beckets so that they were properly affixed and located on ring buoy |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed broken access fence/gate that leads to the pool deck beside locked maintenance door which is not self closing/self latching. Unable to verify if alarmed. Door from bathrooms onto the pool deck not alarmed or latching at the time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Discussed making maintenance gate a part of pool barrier, if maintenance door is left uncorrected.
*Permit Item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs within 6 Ft of pool.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
*Corrected - Operator moved chair to be further than 6 Ft from waters edge. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed no spare pump basket at time of inspection. Pump Intellifo VSF 011533
.2518(e) Provide a spare basket for pump.
*Permit Item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemical and pump in small shed, not meeting compliance. Chemicals were present on the floor in pump shed. Observed wet floor in pump shed. Observed no floor drain present in pump shed. Observed no ventilation. Observed less than 3 ft of clear walking space. Observed ceiling height less than 7 Ft. Observed chemical stored on the floor and wet chemical bags.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(d) Provide drain in pump room floor.
.2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed glass soap dispensers in male and female restrooms at the time of inspection.
.2526(j) Provide soap and soap dispenser, no glass, at each sink. |