Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMADISON SOUTHPARK II
Address4610 COLONY RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/15/2026
Final Score @ Grade
42
General CommentsIssued Immediate Suspension for water quality. Pool MUST REMAIN CLOSED with signage posted until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Will verify other permit items at return visit: weirs, gates/doors/fencing, depth/No Diving markers, spare pump basket and records. “E” Immediate Suspension item. Note: Pool hours listed as 10 am-10pm. Night swimming not permitted. Change signage to reflect no night swimming. Flow meter must remain operable between 78-98 gpm. Inspection with Michael Morsch, REHS and Jaxon Goldenberg-Sheets

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH over 8.2 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Calcium recorded as Cyanuric acid, Incorrect chemical readings, and maintenance checks not accurate. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit Item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed missing weirs at the time of the inspection. .2518(k) Replace missing weirs. *Permit Item
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No No diving and depth markers faded on the deck at the time of the inspection. .2523(c) Depth markers and “No Diving” shall be 4 inches in height and of a contrasting color with the background, clearly visible. *Permit Item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Missing slip resistant tread on the bottom ladder rung at the time of the inspection. .2521(b) Ladders shall have slip-resistant tread.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Beckets were not properly secured so that they were no longer aligned per USCG issuance. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. *Corrected - Operator adjusted beckets so that they were properly affixed and located on ring buoy
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed broken access fence/gate that leads to the pool deck beside locked maintenance door which is not self closing/self latching. Unable to verify if alarmed. Door from bathrooms onto the pool deck not alarmed or latching at the time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Discussed making maintenance gate a part of pool barrier, if maintenance door is left uncorrected. *Permit Item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs within 6 Ft of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. *Corrected - Operator moved chair to be further than 6 Ft from waters edge.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed no spare pump basket at time of inspection. Pump Intellifo VSF 011533 .2518(e) Provide a spare basket for pump. *Permit Item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical and pump in small shed, not meeting compliance. Chemicals were present on the floor in pump shed. Observed wet floor in pump shed. Observed no floor drain present in pump shed. Observed no ventilation. Observed less than 3 ft of clear walking space. Observed ceiling height less than 7 Ft. Observed chemical stored on the floor and wet chemical bags. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(d) Provide drain in pump room floor. .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed glass soap dispensers in male and female restrooms at the time of inspection. .2526(j) Provide soap and soap dispenser, no glass, at each sink.