Premises Information

Return to Inspections
NameMADISON SOUTHPARK II
Address4610 COLONY RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/2/2024
Final Score @ Grade
20
General CommentsInspection completed with Andres Tejada and Brett Furr present. Note: 911 operator indicated excessive static during phone call however she could still clearly hear EHS. Recommend contacting Kings 3 to have phone serviced to ensure the phone is in good repair. In field plan review completed, see below. 1. Flow meter operable and between 78-98gpm. Observed flow at 90GPM. 2. PENTAIR INTELLIFLO VSF 011533. Verified and accurate. 3. Blue white flow meter properly installed. Observed flow meter installed correctly with adequate pipin on both sides of meter. 4. Piping 3” diameter. Observed and accurate. 5. (2) Aquastar 914 main drain covers. Verified and accurate. 6. (4) Aquastar 6HPHA equalizer line covers. Verified and accurate. 7. PENTAIR TR 100C filter. Verified and accurate. 8. (8) floor returns. Verified and accurate.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.8ppm. CDI- adjusted to 3.0ppm through automatic liquid chlorinator.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing or damaged skimmer basket. Observed skimmer baskets in poor repair. CPO indicated baskets already ordered.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one equalizer line covering not securely attached to wall. CDI- capped inside skimmer so no suction hazard present. E. Freese will make return visit on August 9, 2024 to verify equalizer line is securely attached to wall. An intent to suspend the permit may be issued if not secured by this time.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed body hook attached to 8 foot telescoping pole. CDI- body hoke securely affixed to 12 ft pole. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 52 feet. CDI- adjusted to 30 feet.