Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMADISON SOUTHPARK I
Address4605 COLONY RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/16/2024
Final Score @ Grade
20
General CommentsImmediate suspension issued. .2535(1) Maintain pH at 7.2 to 7.8. .2530(f) Emergency phone shall remain operable. Contact Chris Sells at 704 576 8678 for inspection to reopen pool. Observed pool automatic vacuum in pool while pool is open. Pool must be closed to operate vacuum. Recommend replacing ring buoy Repaint no diving and 3’ depth marker

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH below 7.2. Immediate suspension item. .2535(1) Maintain pH at 7.2 to 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed Cl recorded as orp. Use test kit and list Chlorine levels in ppm. Observed no records since 11/25. Maintain records daily as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed top ladder rung missing antislip tread. .2521(b) Ladders shall have slip-resistant tread.
22 6 Premises: emergency telephone provided No No No Observed emergency phone not operating. Immediate suspension item. .2530(f) Emergency phone shall remain operable.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed no chemical storage room. Chemicals stored in pump room. .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft. Observed pump room ceiling less than 7’. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft.