2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine level in pool measured 0.0 ppm. Pool Operator stated circuit panel for automatic chlorinator was damaged and service request was submitted for repair. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. PH level measured 8.4 |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. PDSC form uploaded on 5/20/24 states PDSC form not approved due to waiting on additional information. Provide updated PDSC form. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed 2 missing weirs and 1 weir hanging off of hinge. Replace missing weirs. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Two lounge chairs observed within 6 feet of pool. Operator relocated chairs outside of 6 feet. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Emergency phone was hidden behind wall outside of pool area. Provide signage with location of emergency phone. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(e) Provide a spare basket for pump. No spare basket for pump was available. Obtain a spare pump. |