Inspection Date 8/4/2026
Final Score @ Grade
12
General CommentsConducted inspection with CPO. Pool remains in good standing and on A status. Ensure flow meter reads between 60 and 67 GPM for turnover and flow restriction of return line. Permit Restriction: Flow meter must remain operable. Flow required at 60 to 67 gpm to meet turnover and flow restriction of the return line. Flow greater than 100 gpm exceeds the main drain flow. Suction Hazard. Pump should be set at 3450RPM. Note: Hydrostat is center drain Const. Date: 1/1/1975 Rope Length: 30' Night Swim?: N

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing rubber cap at deep end. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Two ring buoys and ropes present on pool deck. One ring buoy rope length is out of compliance. Operator removed incorrect ring buoy and rope from pool deck. One compliant ring buoy and rope remains on pool deck. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pool built in 1975. Door to pump room not locked at time of inspection. No clear walking space around equipment. Chemical stored in pump room. Some water on floor around filter. Piping goes outside of equipment room. No drain observed in pump room. No backflow prevention on hose bib. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(d) Provide drain in pump room floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
27 2 Equipment room: filter backwash discharged through an air gap No No No Pool built in 1975. No air gap observed at backwash. .2513(b) Filter backwash shall be discharged through an air gap.