Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Four records missing from end of September. Ensure daily records are kept. All previous records kept regularly. No permit action. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Two ring buoys and ropes present on pool deck. One ring buoy rope snapped and rope length is out of compliance. Operator removed ring buoy and rope from pool deck. One compliant ring buoy and rope remains on pool deck. No permit action. |
|
19
|
4
|
Premises: signs prohibit glass containers or pets in pool area |
No |
No
|
No |
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area.
Signage missing prohibition of pets. Sign placed. No permit action. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pool built in 1975. Door to pump room not locked at time of inspection. No clear walking space around equipment. Chemical stored in pump room. Some water on floor around filter. Piping goes outside of equipment room. No drain observed in pump room. No backflow prevention on hose bib.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(d) Provide drain in pump room floor.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Pool built in 1975. No air gap observed at backwash. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Restrooms, missing soap for handwashing.
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
Operator placed soap and corrected. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bibs or drains in restrooms. Pool built in 1975. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.
.2526(c) Floor drains shall be provided in restrooms. |