Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARD BILLY GRAHAM
Address321 W WOODLAWN RD
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/1/2025
Final Score @ Grade
22
General CommentsConducted inspection with CPO Luis and EHS Kurtis. Pool remains on A status and in good standing. Emergency phone operational but receiver is staticky. EHS recommends replacing phone for clearer calls. Pool heater present but not operational. Const. Date: 1/1/1975 Rope Length: 30' NO NIGHT SWIMMING PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE. FLOW SHALL RANGE FROM 60 TO 67 GPM DUE TO FLOW RESTRICTION OF RETURN LINE AND DRAIN COVERS. PUMP SHALL REMAIN SET AT 3450 RPM. HYDROSTAT CENTER DRAIN

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Four records missing from end of September. Ensure daily records are kept. All previous records kept regularly. No permit action.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Two ring buoys and ropes present on pool deck. One ring buoy rope snapped and rope length is out of compliance. Operator removed ring buoy and rope from pool deck. One compliant ring buoy and rope remains on pool deck. No permit action.
19 4 Premises: signs prohibit glass containers or pets in pool area No No No .2530(d) Provide a sign prohibiting pets and glass containers in the pool area. Signage missing prohibition of pets. Sign placed. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pool built in 1975. Door to pump room not locked at time of inspection. No clear walking space around equipment. Chemical stored in pump room. Some water on floor around filter. Piping goes outside of equipment room. No drain observed in pump room. No backflow prevention on hose bib. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(d) Provide drain in pump room floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
27 2 Equipment room: filter backwash discharged through an air gap No No No Pool built in 1975. No air gap observed at backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Restrooms, missing soap for handwashing. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Operator placed soap and corrected.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bibs or drains in restrooms. Pool built in 1975. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. .2526(c) Floor drains shall be provided in restrooms.