Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTONE GROVE AT WHITEHALL - POOL
Address7700 STONEGROVE LN
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/22/2025
Final Score @ Grade
22
General CommentsConducted inspection with operator Gage. Pool must remain closed. Immediate suspension upheld for direct chlorination. Pool must install new chlorinator and cease direct chlorinating to maintain chlorine level. Call EHS Devon when corrected and ready to open. 7049981122 Intent to suspend items must be corrected upon return or 30 day intent to suspend may be issued. Pool does not have equalizers. Cap open equalizer line inside each skimmer. No suction hazard. Ensure ring buoy and body hook are visible from all parts of the pool. Const. Date: 4/14/2006 Rope Length: 50' No night swimming No listed permit conditions

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Chlorinator missing from main pool pump room. Operators have been direct chlorinating to maintain chlorine level. Chlorination must occur through chlorinator. Immediate suspension item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment should be conveniently located. Ring buoy rope tangled. Operator untangled and corrected. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Window limiters missing on middle windows on either side of back clubhouse door, back kitchen window, and back conference room window. Install limiters to prevent windows from opening more than 4”. Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Erosion chlorine feeder missing from main pool pump setup. Pools must be equipped with an automatic chlorinator. Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Water on the floor of the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals stored in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(6) Provide sufficient lighting in chemical storage room. Light not operational in chemical storage room.