| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records for the last two weeks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Two of 4 weirs stuck. .2518(k) Provide functional weirs. - Intent to suspend item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Window to right of Warning-No Lifeguard on Duty sign open > 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Intent to suspend item.
Back gate sticks, doesn’t always self-latch. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck cracked with loose pieces of concrete. .2537(2) Decks shall be kept in good repair. - Intent to suspend item.
Coping loose at sunshelf. .2537(3) There shall be no loose coping. - Intent to suspend item. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Primary rules sign partially obscured by new cabana’s. Not easily visible. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some pool piping not labeled or labels wearing off. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair.
Toilet in men’s restroom running. 2526(m) Keep restrooms and fixtures clean and in good repair. |