Premises Information

Return to Inspections
NameAYRSLEY LOFTS
Address9336 KINGS PARADE BV
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/2/2025
Final Score @ Grade
12
General CommentsLifted suspension. Issued permit. No Night Swimming. Pool not heated. Permit Restriction: Filtration pump flow meter must remain operable with flow at 84 gpm to 98 gpm to meet turnover and flow restriction of the filter. Verified following and found noted differences: New Pump Hayward HCP2500VSP, 2.7 THP Blue white flow meter installed on 2” line reading 85 gpm. (This was original suspension item from expired ITS, corrected), label piping. Main Drain and Skimmer 4” line; Return 3” line at floor with 2” tie in. Main drain and skimmer coming out of ground are 4” and all change to 2” piping for filtration and skimmer. (2) Aquastar R12MFxxx 2017 drain covers (4 total drains) Pentair TR100C filter. 6 wall returns (autofill also has a return fitting on it). This is actually 5 wall returns, 1 floor return at sunshelf for 6 returns, 1 autofill with return fitting and vacuum line covered (4) skimmers Inspection with Tripp Arcury

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not latching at time of inspection. Observed windows open onto pool deck more than 4”. Planter against resident fencing creating horizontal less than 45”. .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. .2528(b) Horizontals shall not be located less than 45" in height. Operator adjusted gate to self-close, self latch. Windows were shut and secured to not open more than 4”. Planter moved back from fencing to eliminate horizontal. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair. No soap in women’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.