8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir missing. .2518(k) Provide functional weirs.
One skimmer not functioning. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Permit item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook with one screw. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Permit item.
Outer rope on ring buoy heavily worn. .2530(a) Provide USCG approved ring buoy with attached 42 foot throw rope at least 1/4 inch in diameter. - Permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not visible from most of the pool deck. Signage directing bathers to the phone location heavily faded, not legible. .2530(f) Emergency phone shall be visible from all areas inside pool enclosure. - Permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Metal bobber heavily corroded. .2518(g) Keep flow meter operational. - Permit item.
Filter pressure gauge not functioning. .2519(k) Provide operational pressure gauge on filter. - Permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Faucets in both restrooms do not stay on to allow for proper handwashing. .2526(m) Keep restrooms and fixtures clean and in good repair. |