Inspection Date 7/14/2026
Final Score @ Grade
2
General CommentsInspection conducted with CPO Jose Rivera. Observed flow meter for filtration pump programmed to above 80 gpm. CPO corrected during inspection and EHS observed flow meter was now reading 79 gpm. Feature pump flow meter was at correct gpm. Permit Restrictions: 1) Filtration Pump Flow meter shall remain operable. Flow shall be maintained at 68 gpm to 80 gpm to meet turnover and flow restriction with number of returns. 2)Feature Pump Flow meter shall remain operable. Flow shall be maintained at 105 gpm to meet flow restriction of 2” return line. 3) Pool is not approved for salt as primary chlorination. NO NIGHT SWIMMING. Construction date: 9/01/2023 Rope length: 45'

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed bags of sodium bicarbonate stored directly on the floor inside chemical storage room. CPO removed bags off of the floor.