47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. water is leaking from the walk-in freezer condenser, currently not dripping onto boxes of food. Observed minor peeling paint with rust on wire shelving ends inside four door reach-in refrigerator. |
|
56
|
0.50
|
Meets ventilation & lighting requirements; designated areas used |
No |
Yes
|
No |
**6-303.11 The light intensity shall be at least 10 foot candles in walk-in units and dry storage areas; 20 foot candles inside reach-in units, handwashing and warewashing areas, equipment storage, toilet rooms, and self-service areas; and 50 foot candles at surfaces where food prep occurs. The lighting in the walk-in refrigerator is reading at a range of 3 to 9 foot candles 30 inches above the floor. The lighting in the walk-in freezer is reading at 4 to 16 foot candles 30 inches above the floor. Need to provide at least 10 foot candles 30 inches above the floor. Repeat |