43
|
0.50
|
In-use utensils: properly stored |
No |
No
|
No |
3-304.12 (E) In-use utensils, such as ice scoops or utensils for non-TCS food, must be stored in a clean and protected location. Observed ice scoop on top of ice machine which was dusty/hair. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-205.10 Ensure equipment other than toasters, mixers, microwaves, water heaters and hoods is ANSI certified or equivalent. Repeat-Observed household air fryer. Air fryer must go home. Air fryer (if commercial) would be located under a fryer |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
Yes |
No
|
No |
4-303.11 (A) (B) Cleaning agents and chemical sanitizers that are used to clean and sanitize equipment and utensils shall be provided and available for use during all hours of operation.-Pf. Observed sanitizer dispenser not operating. Sanitizer container low, no extra sanitizer to trade out. Facility did have bleach test strips. CDI-manager ran and purchased bleach. Demonstration of how to use bleach and to use test kit. |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed leak at valve on 3-comp sink-needs repair |
|
54
|
1
|
Garbage & refuse properly disposed; facilities maintained |
No |
Yes
|
No |
5-501.13 Receptacles for refuse, recyclables, and returnables shall be durable, cleanable, insect- and rodent-resistant, leakproof, and non-absorbent. Repeat- Observed ground around dumpster and recycling bin sludgy/greasy. Trash on ground. Dumpster missing drain plug. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Repeat- Observed floor in men’s bathroom in disrepair. |