38
|
0
|
Insects & rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.111 Keep the premises free of insects, rodents, and other pests.
EHS observed a few flying pests in kitchen during visit.
-0- |
|
41
|
0.50
|
Wiping cloths: properly used & stored |
Yes |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses.
EHS obsevred wiping clothes stored in sanitizer solution at 0ppm.
CDI- PIC refreshed sanitizer to correct concentration.
-0.5- |
|
49
|
1
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. EHS observed visible food debris present on shelves of prep units.
*REPEAT -1- |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair.
EHS Obsevred grates in floor on the cook line in need of resealing. EHS observed food debris present in the gaps between grate and the flooring.
-0-
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure.
EHS observed residue present on ceiling tiles above back prep area. Clean/replace
-0- |