44
|
0
|
Utensils, equipment & linens: properly stored, dried & handled |
Yes |
No
|
No |
4-903.11 (B) Equipment, Utensils, Linens and Single-Service and Single-Use Articles Storing (C) Observed drinking mugs, beside the coffee maker, stored upright. (B) Clean EQUIPMENT and UTENSILS shall be stored (2) Covered or inverted. EHS Suggested placing tray over mugs, or turning them upside down to keep dust, splash, or other contamination out. CDI - PIC stated a tray was placed over the mugs. |
|
51
|
1
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-202.13 Backflow Prevention, Air Gap. -P Observed the pipe under the prep sink below the flood level rim, which can cause cross contamination if backflow occurs. An air gap between the water supply and flood level rim shall be at least twice the diameter of the water supply inlet and not less than 1 inch. Suggested maintenance fix the issue. Also, under the 3 comp sink for the dish drain, the pipe is level with the flood rim. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 Provide required lighting intensity. There isn't any lighting above the prep sink where they prep meat and vegetables. The light intensity shall be: (C) At least 50 foot candles at a surface where a food employee is working with food or working with utensils or equipment such as knives, where employee safety is a factor. |