5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Total alkalinity observed not checked in more than week.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One out of 7 weirs missing.
.2518(k) Replace missing weirs. Weir has been ordered, waiting on tech to install. Lack of severity does not warrant permit action at this time. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope tangled at time of inspection. .2530(a) Lifesaving equipment should be conveniently located. Keep accessible. Operator untangled and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Doors onto pool deck not latching or alarmed at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator adjusted to alarm. Alarms are turned on to doors when establishment opens for the day to public. Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Teaching platforms, lane lines, blue benches and equipment within 5’ of pool. Pool closed to public and being vacuumed at time of inspection.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Per operator, this was removed from pool for cleaning and will all be in the pool, for teaching or outside the pool space when pool is open to the public, moved some items back. Since pool is not currently operating and items will be moved, did not take permit action. Correction and compliance will be met when opened to public. Per operator, all items are moved into the pool for operation. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
VFD set at 400 and reading 407 gpm. Permit restriction, VFD must remain operable and not exceed 350 gpm. Operator adjusted speed and corrected to set speed 350, VFD displaying 347 gpm. Advised monitoring this daily. Corrected. |