Premises Information

Return to Inspections
NameBLAKE OPTIMIST PARK, THE
Address2006 N BREVARD ST
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2025
Final Score @ Grade
18
General CommentsOBSERVED NEW MOTOR FOR FEATURE PUMP. MOTOR SWAP MUST HAVE ELECTRICAL PERMIT AND INSPECTION WITH MECKLENBURG COUNTY CODE ENFORCEMENT. OBSERVED THE FEATURE PUMP TO BE A HAYWARD HCP20203 PUMP 2.7 HP ON A 2 HP MOTOR. WHAT IS ON THE APPROVED PDSC FORM IS A HAYWARD HCP20153 1.5 HP PUMP. THIS IS NOT AN APPROVED CHANGE. THE NEW PUMP MUST BE RECORDED ON A PDSC FORM, SUBMITTED TO THE HEALTH DEPARTMENT FOR APPROVAL, AND APPROVED. THE BUBBLER FEATURES WERE TURNED OFF TO AVOID CLOSURE ORDER BY THE HEALTH DEPARTMENT. THEY CANNOT BE TURNED BACK ON UNTIL THE NEW PUMP AND MOTOR ARE APPROVED. PROVIDE WHATEVER RESOURCES ARE NEEDED TO MAINTAIN POOL IN PROPER CONDITION, INCLUDING CLEANING THE POOL AND MAINTAINING THE DECK. GPM FOR FEATURE WAS 110 GPM AND FILTRATION WAS 75 GPM

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed unapproved pump and motor swap for the bubbler feature. Bubbler feature was turned off. Do not turn bubbler feature back on until the change is approved and verified by the Health Department.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed throw rope to be 48 feet 10 inches, not 50 foot as required. Rope was untangled and met the 50 foot requirement. Observed hook not attached to the pole. Hook was attached. Do not remove the hook from the pole. -CDI.
22 6 Premises: emergency telephone provided No No No Observe wrong phone number posted at the call box. Correct number was posted. 254-585-3530 -CDI