Premises Information

Return to Inspections
NameCONNERY ON PROVIDENCE
Address4520 SHADY STREAM WY
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/25/2025
Final Score @ Grade
20
General CommentsImmediate suspension issued for water quality. Pool must remain closed. Signs posted at every bather entrance until suspension is lifted by Health Department. Changed to E immediate suspension status. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Will verify other permit items at return visit” records, cyanuric acid and doors from permit restriction. Access shall be maintained to units 124 172 174 and 176 as patio doors are the pool barrier gates. Salt not approved his primary chlorination Observed animals on pool deck at time of inspection. Advised pets are not permitted in pool area.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Récords not kept for last week and entries not accurate (same reading every day for months and no maintenance). Cyanuric acid over 200 ppm. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Debris in skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Doors from two required resident rooms onto patio not latching. Permit restriction Access shall be maintained to units 124 172 174 and 176 as patio doors are the pool barrier gates do not meet code. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals in pump room. Some items within 3 foot pf equipment. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.