Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSOLIS MIDTOWN APARTMENTS
Address1133 HARDING PL
 
City/State/ZIP
CHARLOTTE NC 20204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/21/2026
Final Score @ Grade
24
General CommentsInspection conducted with CPO Alex Morales. Alex is the new CPO for this pool, provide copy of CPO certification. Property now managed by RPM Living. Emailed copy of application to the manager to update and email back. Permit condition that feature pump flow meter must remain operable. Flow required at 62 gpm or less due to suction pipe flow restriction. Verified at 48 GPM today. Permit condition that Filtration pump flow meter must remain operable. Flow required at 83 gpm to 120 gpm to meet turnover and return # restriction. Verified at 118 GPM today. Outer rope on ring buoy frying. Recommend replacing with new US Coast Guard approved ring buoy with attached 50 foot throw rope at least 1/4 inches in diameter. Kings III had difficulty hearing me, static on the line. Recommend having Kings III check the emergency phone. Immediate suspension issued 3) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. New CPO. Provide CPO certificate to our office. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing one eyeball fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Most of the fence < 48” high. Ensure no gaps > 2” under the fence after removing mulch. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorine feeder not functioning. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.