3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH at 7.0
Immediate suspension. Raised to 7.1 during inspection
.2535(1) Maintain pH at 7.2 to 7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Repeat: Observed no records of cyanuric acid for the last 9 days
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gate near pump house not self-latching. Latch mechanism not properly functioning.
Corrected during inspection.
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not functioning during inspection. Kings III issues on Kings III side, corrected during inspection.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed exhaust fan not functioning.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |