10
|
0
|
Handwashing sinks supplied & accessible |
No |
Yes
|
No |
5-202.12 Provide at least 100F water at handsinks. The handwash lavatory still fluctuates from 73 - 116 degrees F. It shall consistently be at leas 100 degrees F. A hand hygiene protocol shall be implemented to use hand sanitizer after washing. |
|
39
|
1
|
Contamination prevented during food preparation, storage & display |
No |
Yes
|
No |
3-305.14 Food Preparation (C) The hood ANSL is still dripping onto the skillet. The skillet is not being used today but this hazard shall be eliminated. Also, the vents along the HVAC trunk along the wall are condensating onto the clean utensils on the sink drainboard and at the food prep sink where produce is washed. Measures shall be taken such at relocating clean air drying utentils and not washing produce in the compartment directly under the drips. Have maintenance called to address these potential sources of contamination. |
|
47
|
1
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-501.11 Maintain equipment in good repair. The dishmachine is still not sanitizing. Staff state they prefer and use the utensil sink to wash rinse and sanitize. It is set up today as approved for 2 comp usage with wash, running water rinse, and sanitize. The 3rd compartment will not hold water due to food grinder being removed and the drain opening is too large. The hood system is not keeping condensation from dripping onto the cooking surfaces.
4-205.10 Ensure equipment other than toasters, mixers, microwaves, water heaters and hoods is ANSI certified or equivalent. There are many inverted milk crates being used throughout as shelving. |
|
51
|
2
|
Plumbing installed; proper backflow devices |
No |
Yes
|
No |
5-205.15 Maintain a plumbing system in good repair. The canwash faucet is still leaking and water is still standing in the canwash drain. These items shall be maintained in good repair. |
|
54
|
0.50
|
Garbage & refuse properly disposed; facilities maintained |
No |
Yes
|
No |
5-501.114 Drains in dumpsters and waste containers shall have drain plugs in place. One dumpster has an open door and the drain plug is missing. Maintain doors and lids closed to help prevent the entrance of vermin. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. The leak hole is still present in the dishmachine room ceiling. Areas in the main kitchen where the ceiling has been painted are beginning to exhibit cracked paint and will be peeling over the prep table. Maintain all surfaces in good repair.
6-501.11 Repairing - Premises, Structures, Attachments, and Fixtures - Methods (C)
6-501.16 Drying Mops (C) hang mops head down for air drying. |