Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSOUTH AND HOLLIS
Address3441 SOUTH BV
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/15/2025
Final Score @ Grade
12
General CommentsPerformed inspection with onsite operator Toriano. Intent to suspend issued for insufficient records. Records must be consistently kept for 30 days or permit suspension may be issued. Feature pump 40gpm Const. Date: 2/1/2024 Rope Length: 31'6 No night swimming. Permit Restrictions: 1) Filtration flow meter must remain operable. Flow shall be maintained from 47 gpm to 63 gpm to meet turnover and flow restriction of the filter. 2) Flow meter on feature pump flow shall not exceed 104 gpm to meet flow restriction of return line. 3) Pool is not approved for salt as primary chlorination. 4) Sump pump required for means to empty swimming pool. 5) Lock must remain in place on disconnect lock out for ventilation in chemical storage room. Note: Filtration pulls through skimmers only. Not tied to main drains. Hayward drain cover is hydrostat

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Records missing since May 2025. Half of May missing. CPO found records for September and October. Weekends missing. Records MUST be kept daily and weekly, even on weekends. Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Deck loungers too close to pool edge. Operator corrected. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals stored in pump room. Ensure all chemicals remain in designated chemical storage room.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(h) Shower(s) shall be provided. .2526(a) Post a shower sign visible upon entrance to the pool.