22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Chicken stew in the walk in cooler 47F. Per kitchen staff the chicken was made yesterday and was sent to the walk in to cool overnight. Maintain TCS foods in cold holding at 41F or less. -P CDI, voluntary discard. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
No |
4-302.13 (B) Facility unable to locate plate thermometer during the inspection. Provide an approved Max/Min thermometer for testing sanitizing temperatures in hot water warewashing machines. The thermometer must be readily accessible. -Pf Verification required. |
|
51
|
1
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-202.13 Spray arm for the warewashing machine pre rinse hanging down into the sink basin past the flood rim of the pre rinse sink basin. An air gap between the water supply and flood level rim shall be at least twice the diameter of the water supply inlet and not less than 1 inch.-P Verification required. |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.114 Drain plug missing on outside cardboard dumpster. All waste receptacles with drains shall have drain plugs in place. |