Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePROSE RHYNE
Address2215 RED GARNET DR
 
City/State/ZIP
CHARLOTTE NC 28214
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/25/2026
Final Score @ Grade
12
General CommentsInspection conducted with Newton Munoz. Flow was initially observed at 53 gpm. A backwash was performed and adjustments made during the inspection to bring the flow to 118 gpm. No night swimming. Const. Date: 9/14/2023 Rope Length: 50‘ Permit Restriction: Flow shall be set at max speed or flow meter shall remain operable with flow at 92 gpm to 138 gpm to meet turnover and flow restriction of suction line. Inspectors Info: Kurtis Nelson 980-378-7896

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. TA and CA were not being kept weekly on records. Record log provided did not have an area for main drain checks. New record log was printed by operator to use that meets requirements of all daily and weekly records. No permit action.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers with an accumulation of debris. All cleaned during the inspection. CDI
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Equipment was observed being stored within 3 ft of the valves and controls in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap present in both restrooms.