8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir missing out of 5.
.2518(k) Replace missing weirs. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gap greater than 2” under fence by left entry.
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).
*permit item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone not working at time of inspection. .2530(f) Emergency phone shall remain operable.
*Immediate suspension |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Hose in pump room, not allowing 3 foot clearance around piping. Bucket of chemicals holding chemical room door open in pump room. Gallon of muratic acid of shelf above dry chemicals. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Toilet soiled in restroom.
.2526(m) Keep restrooms and fixtures clean and in good repair. |