14
|
1
|
Required records available: shellstock tags, parasite destruction |
No |
No
|
Yes |
3-203.12 Retain tag on the bag of shellstock until empty. Record date on the tag when the last shellstock from the container is used. Store tags in chronological order for 90 days. -Pf
Observed no dates marked on tags of last shell stock used and tags were out of order (stored in a plastic bag). EHS explained reason for marking dates and gave example of a chronological storing system. A verification will be conducted within 10 days to verify dates applied to tags and system for holding tags id being utilized. - 1 - |
|
51
|
1
|
Plumbing installed; proper backflow devices |
Yes |
No
|
No |
5-202.13 An air gap between the water supply and flood level rim shall be at least twice the diameter of the water supply inlet and not less than 1 inch.-P
Observed sprayer laying below flood level rim of pre wash drain board. Adjust spring or utilize another way to keep sprayer above flood rim. CDI - PIC placed sprayer on holder that keeps it above flood rim. - 1 - |