Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRESERVE AT STONE HOLLOW
Address8800 HOLLOW CREEK CIR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/17/2026
Final Score @ Grade
14
General CommentsInspection conducted with CPO Mohammad Safi. New pump motor installed. Electrical permit COM-ELC-26-005488 passed 6/15/2026. New TR 140C filter installed. Verified in-field plan review items. Verified flow at 110 GPM after a backwash at 3200 RPM. New permit condition that flow meter must remain operable and be between 98 and 120 gpm for minimum turnover and flow restriction of the number of returns. WARNING NO LIFEGUARD ON DUTY sign some wording is less than 4”. Will need to provide extra signage in at least 4” lettering. Some cracked depth markers, missing grout around no diving marker. Maintain in good condition. Kings III phone cuts in and out. Maintain in good condition. Recommend having Kings III check the emergency phone. Permit issued with the following conditions: No night swimming Flow meter must remain operable. Flow required at 98 to 120 GPM to meet turnover and flow restriction of the number of returns. Paper permit will be on our website, https://eh.mecknc.gov/pools, in 1-3 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Plugs missing in skimmer equalizer lines. .2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. - Will follow up with facility to ensure corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water comes out of the pump room floor drain when backwashing. .2533(d) Pump room floor shall be kept dry and free of standing water. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some bags of chemicals on the ground in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One light burned out, other light flickering in men’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.