General CommentsInspection conducted with CPO Clay Massenburg and the property manager. Conducted pre-permit inspection. Verified items from previous inspection as well. Pool gates with < 45” between horizontals. Prior to 2025 permit being issued. Will need to eliminate footholds by installing metal mesh, plexiglas, or equivalent on the outside of the gates or replacing with new gates that meet requirements in .2528. Permit issued No Night Swimming Paper permit will be available on our website for your records in 3-5 business days.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level below the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 barrier wall by stairs and some sections of fencing less than 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Back gate not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone number does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in pump room and chemical storage room. .2533(d) Pump room floor shall be kept dry and free of standing water.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No toilet paper in one of the stalls in the women’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms.