Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAXIS AT THE PARK
Address5200 OXFORD POND DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/29/2024
Final Score @ Grade
22
General CommentsIssued immediate suspension for pH and body hook/pole issues. Pool is to remain closed until items have been corrected. Once corrected, call James Bjorneboe st 704-507-6820 to schedule re-visit. General Comment: Unable to access pump room and chemical room at time of inspection. Further permit action might be required at time of revisit if pump room and chemical rooms remain inaccessible.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH at 6.8. Maintain pH between 7.2 and 7.8. .2535(1) Maintain pH at 7.2 to 7.8.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed excessive debris in pool skimmers. Keep pool skimmers free of excessive debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed missing end cap on one ladder. Replace. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed one body hook not attached to pole. Observed other body hook attached to a retractable/ telescoping pole. Hooks must be attached to a single piece pole at least 12 feet in length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gate closest to clubhouse not self- latching. Ensure all gates are kept self-closing/ self-latching. .2537(b) All gates and doors shall be self-closing, self-latching.