47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
Yes |
No
|
No |
4-101.11 (A) - (E ) Food contact surfaces shall be (A) Safe P, (B) Durable, Corrosion-Resistant, (C ) sufficient in weight and thickness to withstand repeated washing (D) Smooth and easily cleanable, and (E) Resistant to damage. Observed wooden pestle with dark cracks and grooves. CDI - PIC voluntarily discarded wooden pestle
4-501.11 Maintain equipment in good repair. Observed a few tongs and serving spoons with melted plastic handle. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed interior walls of WIC with food debris and splash. Increase frequency of cleaning. |
|
56
|
0.50
|
Meets ventilation & lighting requirements; designated areas used |
No |
Yes
|
No |
REPEAT
6-501.14 Change the filters and clean the intake and exhaust air ducts so they are not a source of contamination by dust, dirt or other materials. Observed both hood filters with grease build up.
4-301.14 Hood systems and devices shall be in sufficient number and capacity to prevent grease or condensation from collecting on equipment, walls, and ceilings. Observed hood system without drain pan at fryer station. PIC is currently using towels to capture any dripping from hood filters. |